Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Talanta ; 260: 124604, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2316564

RESUMEN

Herein, a ternary PdPtRu nanodendrite as novel trimetallic nanozyme was reported, which possessed excellent peroxidase-like activity as well as electro-catalytic activity on account of the synergistic effect between the three metals. Based on the excellent electro-catalytic activity of trimetallic PdPtRu nanozyme toward the reduction of H2O2, the trimetallic nanozyme was applied to construct a brief electrochemical immunosensor for SARS-COV-2 antigen detection. Concretely, trimetallic PdPtRu nanodendrite was used to modify electrode surface, which not only generated high reduction current of H2O2 for signal amplification, but also provided massive active sites for capture antibody (Ab1) immobilization to construct immunosensor. In the presence of target SARS-COV-2 antigen, SiO2 nanosphere labeled detection antibody (Ab2) composites were introduced on the electrode surface according sandwich immuno-reaction. Due to the inhibitory effect of SiO2 nanosphere on the current signal, the current signal was decreased with the increasing target SARS-COV-2 antigen concentration. As a result, the proposed electrochemical immunosensor presented sensitive detection of SARS-COV-2 antigen with linear range from 1.0 pg/mL to 1.0 µg/mL and limit of detection down to 51.74 fg/mL. The proposed immunosensor provide a brief but sensitive antigen detection tool for rapid diagnosis of COVID-19.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanopartículas del Metal , Humanos , Nanopartículas del Metal/química , SARS-CoV-2 , Inmunoensayo , Peróxido de Hidrógeno/química , Dióxido de Silicio , COVID-19/diagnóstico , Anticuerpos , Anticuerpos Inmovilizados/química , Oro/química , Técnicas Electroquímicas , Límite de Detección
2.
ACS Appl Bio Mater ; 4(4): 2974-2995, 2021 04 19.
Artículo en Inglés | MEDLINE | ID: covidwho-1157888

RESUMEN

The current scenario, an ongoing pandemic of COVID-19, places a dreadful burden on the healthcare system worldwide. Subsequently, there is a need for a rapid, user-friendly, and inexpensive on-site monitoring system for diagnosis. The early and rapid diagnosis of SARS-CoV-2 plays an important role in combating the outbreak. Although conventional methods such as PCR, RT-PCR, and ELISA, etc., offer a gold-standard solution to manage the pandemic, they cannot be implemented as a point-of-care (POC) testing arrangement. Moreover, surface-enhanced Raman spectroscopy (SERS) having a high enhancement factor provides quantitative results with high specificity, sensitivity, and multiplex detection ability but lacks in POC setup. In contrast, POC devices such as lateral flow immunoassay (LFIA) offer rapid, simple-to-use, cost-effective, reliable platform. However, LFIA has limitations in quantitative and sensitive analyses of SARS-CoV-2 detection. To resolve these concerns, herein we discuss a unique modality that is an integration of SERS with LFIA for quantitative analyses of SARS-CoV-2. The miniaturization ability of SERS-based devices makes them promising in biosensor application and has the potential to make a better alternative of conventional diagnostic methods. This review also demonstrates the commercially available and FDA/ICMR approved LFIA kits for on-site diagnosis of SARS-CoV-2.


Asunto(s)
COVID-19/diagnóstico , Inmunoensayo/métodos , Sistemas de Atención de Punto , Espectrometría Raman , Proteínas Virales/inmunología , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , Biomarcadores/sangre , Biomarcadores/metabolismo , COVID-19/virología , Humanos , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/metabolismo , Proteínas Virales/metabolismo
3.
Talanta ; 227: 122207, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1078201

RESUMEN

Since December 2019, Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has caused millions of deaths and seriously threatened the safety of human life; indeed, this situation is worsening and many people are infected with the new coronavirus every day. Therefore, it is very important to understand patients' degree of infection and infection history through antibody testing. Such information is useful also for the government and hospitals to formulate reasonable prevention policies and treatment plans. In this paper, we develop a lateral flow immunoassay (LFIA) method based on superparamagnetic nanoparticles (SMNPs) and a giant magnetoresistance (GMR) sensing system for the simultaneously quantitative detection of anti-SARS-CoV-2 immunoglobulin M (IgM) and G (IgG). A simple and time-effective co-precipitation method was utilized to prepare the SMNPs, which have good dispersibility and magnetic property, with an average diameter of 68 nm. The Internet of Medical Things-supported GMR could transmit medical data to a smartphone through the Bluetooth protocol, making patient information available for medical staff. The proposed GMR system, based on SMNP-supported LFIA, has an outstanding advantage in cost-effectiveness and time-efficiency, and is easy to operate. We believe that the suggested GMR based LFIA system will be very useful for medical staff to analyze and to preserve as a record of infection in COVID-19 patients.


Asunto(s)
Anticuerpos Antivirales/sangre , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , SARS-CoV-2/inmunología , Animales , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Antivirales/inmunología , Bovinos , Teléfono Celular , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Internet de las Cosas , Límite de Detección , Nanopartículas Magnéticas de Óxido de Hierro/química , Fenómenos Magnéticos
4.
ACS Appl Bio Mater ; 4(2): 1307-1318, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1069089

RESUMEN

Recent evidence suggests that proinflammatory cytokines, such as tumor necrosis factor α (TNF-α), play a pivotal role in the development of inflammatory-related pathologies (covid-19, depressive disorders, sepsis, cancer, etc.,). More importantly, the development of TNF-α biosensors applied to biological fluids (e.g. sweat) could offer non-invasive solutions for the continuous monitoring of these disorders, in particular, polydimethylsiloxane (PDMS)-based biosensors. We have therefore investigated the biofunctionalization of PDMS surfaces using a silanization reaction with 3-aminopropyltriethoxysilane, for the development of a human TNF-α biosensor. The silanization conditions for 50 µm PDMS surfaces were extensively studied by using water contact angle measurements, electron dispersive X-ray and Fourier transform infrared spectroscopies, and fluorescamine detection. Evaluation of the wettability of the silanized surfaces and the Si/C ratio pointed out to the optimal silanization conditions supporting the formation of a stable and reproducible aminosilane layer, necessary for further bioconjugation. An ELISA-type immunoassay was then successfully performed for the detection and quantification of human TNF-α through fluorescent microscopy, reaching a limit of detection of 0.55 µg/mL (31.6 nM). Finally, this study reports for the first time a promising method for the development of PDMS-based biosensors for the detection of TNF-α, using a quick, stable, and simple biofunctionalization process.


Asunto(s)
Dimetilpolisiloxanos/química , Inmunoensayo/métodos , Factor de Necrosis Tumoral alfa/análisis , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , COVID-19/metabolismo , COVID-19/patología , COVID-19/virología , Carbono/química , Humanos , Inmunoensayo/instrumentación , Límite de Detección , Microfluídica , Microscopía Fluorescente , SARS-CoV-2/aislamiento & purificación , Silicio/química , Factor de Necrosis Tumoral alfa/inmunología , Humectabilidad
5.
Adv Mater ; 33(10): e2007847, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: covidwho-1062095

RESUMEN

The graphene revolution, which has taken place during the last 15 years, has represented a paradigm shift for science. The extraordinary properties possessed by this unique material have paved the road to a number of applications in materials science, optoelectronics, energy, and sensing. Graphene-related materials (GRMs) are now produced in large scale and have found niche applications also in the biomedical technologies, defining new standards for drug delivery and biosensing. Such advances position GRMs as novel tools to fight against the current COVID-19 and future pandemics. In this regard, GRMs can play a major role in sensing, as an active component in antiviral surfaces or in virucidal formulations. Herein, the most promising strategies reported in the literature on the use of GRM-based materials against the COVID-19 pandemic and other types of viruses are showcased, with a strong focus on the impact of functionalization, deposition techniques, and integration into devices and surface coatings.


Asunto(s)
COVID-19/diagnóstico , Grafito/química , Nanoestructuras/química , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Antivirales/química , Antivirales/farmacología , Técnicas Biosensibles/métodos , COVID-19/prevención & control , COVID-19/virología , Técnicas Electroquímicas , Electrodos , Humanos , Límite de Detección , Nanoestructuras/toxicidad , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/metabolismo , Propiedades de Superficie , Proteínas Virales/análisis , Proteínas Virales/inmunología
6.
Anal Chim Acta ; 1147: 30-37, 2021 Feb 22.
Artículo en Inglés | MEDLINE | ID: covidwho-1012278

RESUMEN

Simple, low-cost, and sensitive new platforms for electrochemical immunosensors for virus detection have been attracted attention due to the recent pandemic caused by a new type of coronavirus (SARS-CoV-2). In the present work, we report for the first time the construction of an immunosensor using a commercial 3D conductive filament of carbon black and polylactic acid (PLA) to detect Hantavirus Araucaria nucleoprotein (Np) as a proof-of-concept. The recognition biomolecule was anchored directly at the filament surface by using N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride and N-Hydroxysuccinimide (EDC/NHS). Conductive and non-conductive composites of PLA were characterized using thermal gravimetric analysis (TGA), revealing around 30% w/w of carbon in the filament. Morphological features of composites were obtained from SEM and TEM measurements. FTIR measurement revealed that crosslinking agents were covalently bonded at the filament surface. Electrochemical techniques such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for the evaluation of each step involved in the construction of the proposed immunosensor. The results showed the potentiality of the device for the quantitative detection of Hantavirus Araucaria nucleoprotein (Np) from 30 µg mL-1 to 240 µg mL-1 with a limit of detection of 22 µg mL-1. Also, the proposed immunosensor was applied with success for virus detection in 100x diluted human serum samples. Therefore, the PLA conductive filament with carbon black is a simple and excellent platform for immunosensing, which offers naturally carboxylic groups able to anchor covalently biomolecules.


Asunto(s)
Anticuerpos Antivirales/inmunología , Inmunoensayo/métodos , Proteínas de la Nucleocápside/inmunología , Impresión Tridimensional , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , COVID-19/diagnóstico , COVID-19/virología , Espectroscopía Dieléctrica , Electrodos , Orthohantavirus/aislamiento & purificación , Orthohantavirus/metabolismo , Infecciones por Hantavirus/diagnóstico , Infecciones por Hantavirus/virología , Humanos , Inmunoensayo/instrumentación , Límite de Detección , Proteínas de la Nucleocápside/sangre , SARS-CoV-2/aislamiento & purificación , Hollín/química
7.
Biosens Bioelectron ; 177: 112971, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1009326

RESUMEN

Effective and efficient management of human betacoronavirus severe acute respiratory syndrome (SARS)-CoV-2 virus infection i.e., COVID-19 pandemic, required sensitive and selective sensors with short sample-to-result durations for performing desired diagnostics. In this direction, one appropriate alternative approach to detect SARS-CoV-2 virus protein at low level i.e., femtomolar (fM) is exploring plasmonic metasensor technology for COVID-19 diagnostics, which offers exquisite opportunities in advanced healthcare programs, and modern clinical diagnostics. The intrinsic merits of plasmonic metasensors stem from their capability to squeeze electromagnetic fields, simultaneously in frequency, time, and space. However, the detection of low-molecular weight biomolecules at low densities is a typical drawback of conventional metasensors that has recently been addressed using toroidal metasurface technology. This research is focused on the fabrication of a miniaturized plasmonic immunosensor based on toroidal electrodynamics concept that can sustain robustly confined plasmonic modes with ultranarrow lineshapes in the terahertz (THz) frequencies. By exciting toroidal dipole mode using our quasi-infinite metasurface and a judiciously optimized protocol based on functionalized gold nanoparticles (AuNPs) conjugated with the specific monoclonal antibody specific to spike protein (S1) of SARS-CoV-2 virus onto the metasurface, the resonance shifts for diverse concentrations of the spike protein are monitored. Possessing molecular weight around ~76 kDa allowed to detect the presence of SARS-CoV-2 virus protein with significantly low as limit of detection (LoD) was achieved as ~4.2 fM. We envisage that outcomes of this research will pave the way toward the use of toroidal metasensors as practical technologies for rapid and precise screening of SARS-CoV-2 virus carriers, symptomatic or asymptomatic, and spike proteins in hospitals, clinics, laboratories, and site of infection.


Asunto(s)
Anticuerpos Inmovilizados/química , Técnicas Biosensibles/métodos , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/análisis , COVID-19/virología , Oro/química , Humanos , Inmunoensayo/métodos , Límite de Detección , Nanopartículas del Metal/química
8.
Biosens Bioelectron ; 171: 112685, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: covidwho-891295

RESUMEN

The spread of SARS-CoV-2 virus in the ongoing global pandemic has led to infections of millions of people and losses of many lives. The rapid, accurate and convenient SARS-CoV-2 virus detection is crucial for controlling and stopping the pandemic. Diagnosis of patients in the early stage infection are so far limited to viral nucleic acid or antigen detection in human nasopharyngeal swab or saliva samples. Here we developed a method for rapid and direct optical measurement of SARS-CoV-2 virus particles in one step nearly without any sample preparation using a spike protein specific nanoplasmonic resonance sensor. As low as 370 vp/mL were detected in one step within 15 min and the virus concentration can be quantified linearly in the range of 0 to 107 vp/mL. Measurements shown on both generic microplate reader and a handheld smartphone connected device suggest that our low-cost and rapid detection method may be adopted quickly under both regular clinical environment and resource-limited settings.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas Biosensibles/instrumentación , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Pruebas en el Punto de Atención , Virión/aislamiento & purificación , Anticuerpos Inmovilizados/química , Técnicas Biosensibles/economía , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/economía , Infecciones por Coronavirus/economía , Diseño de Equipo , Humanos , Límite de Detección , Modelos Moleculares , Pandemias , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus/análisis , Factores de Tiempo
9.
Sci Adv ; 6(42)2020 10.
Artículo en Inglés | MEDLINE | ID: covidwho-781066

RESUMEN

To combat severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) and any unknown emerging pathogens in the future, the development of a rapid and effective method to generate high-affinity antibodies or antibody-like proteins is of critical importance. We here report high-speed in vitro selection of multiple high-affinity antibody-like proteins against various targets including the SARS-CoV-2 spike protein. The sequences of monobodies against the SARS-CoV-2 spike protein were successfully procured within only 4 days. Furthermore, the obtained monobody efficiently captured SARS-CoV-2 particles from the nasal swab samples of patients and exhibited a high neutralizing activity against SARS-CoV-2 infection (half-maximal inhibitory concentration, 0.5 nanomolar). High-speed in vitro selection of antibody-like proteins is a promising method for rapid development of a detection method for, and of a neutralizing protein against, a virus responsible for an ongoing, and possibly a future, pandemic.


Asunto(s)
Betacoronavirus/inmunología , Peptidil-Dipeptidasa A/inmunología , Anticuerpos de Dominio Único/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Secuencia de Aminoácidos , Enzima Convertidora de Angiotensina 2 , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Neutralizantes/química , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/metabolismo , Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , COVID-19 , Técnicas de Visualización de Superficie Celular/métodos , Infecciones por Coronavirus/patología , Infecciones por Coronavirus/virología , Dimerización , Humanos , Cinética , Pandemias , Péptidos/química , Péptidos/inmunología , Peptidil-Dipeptidasa A/química , Peptidil-Dipeptidasa A/metabolismo , Neumonía Viral/patología , Neumonía Viral/virología , Dominios Proteicos/inmunología , Subunidades de Proteína/química , Subunidades de Proteína/inmunología , Subunidades de Proteína/metabolismo , ARN Viral/metabolismo , SARS-CoV-2 , Anticuerpos de Dominio Único/química , Anticuerpos de Dominio Único/metabolismo , Glicoproteína de la Espiga del Coronavirus/química
10.
ACS Sens ; 5(9): 2747-2752, 2020 09 25.
Artículo en Inglés | MEDLINE | ID: covidwho-740029

RESUMEN

With the current intense need for rapid and accurate detection of viruses due to COVID-19, we report on a platform technology that is well suited for this purpose, using intact measles virus for a demonstration. Cases of infection due to the measles virus are rapidly increasing, yet current diagnostic tools used to monitor for the virus rely on slow (>1 h) technologies. Here, we demonstrate the first biosensor capable of detecting the measles virus in minutes with no preprocessing steps. The key sensing element is an electrode coated with a self-assembled monolayer containing the measles antibody, immobilized through an N-heterocyclic carbene (NHC). The intact virus is detected by changes in resistance, giving a linear response to 10-100 µg/mL of the intact measles virus without the need to label or process the sample. The limit of detection is 6 µg/mL, which is at the lower limit of concentrations that can cause infections in primates. The NHC-based biosensors are shown to be superior to thiol-based systems, producing an approximately 10× larger response and significantly greater stability toward repeated measurements and long-term storage. This NHC-based biosensor thus represents an important development for both the rapid detection of the measles virus and as a platform technology for the detection of other biological targets of interest.


Asunto(s)
Anticuerpos Inmovilizados/inmunología , Bencimidazoles/química , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Virus del Sarampión/aislamiento & purificación , Anticuerpos Inmovilizados/química , Técnicas Electroquímicas/instrumentación , Electrodos , Oro/química , Límite de Detección , Virus del Sarampión/inmunología
11.
Biosens Bioelectron ; 165: 112361, 2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: covidwho-617487

RESUMEN

The recent outbreak of the coronavirus disease (COVID-19) has left the world clueless. As the WHO declares this new contagion as a pandemic on the 11th of March 2020, the alarming rate of the spawn of the disease in such a short period has disarranged the globe. Standing against this situation researchers are strenuously searching for the key traits responsible for this pandemic. As knowledge regarding the dynamics and host-path interaction of COVID-19 causing Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) is currently unknown, the formulation of strategies concerning antiviral treatment, vaccination, and epidemiological control stands crucial. Before designing adequate therapeutic strategies, it is extremely essential to diagnose the disease at the outset as early detection can have a greater impact on building health system capacity. Hence, a comprehensive review of strategies for COVID-19 diagnosis is essential in this existing global situation. In this review, sequentially, we have provided the clinical details along with genetic and proteomic biomarkers related to COVID-19. The article systematically enlightens a clear overview of the clinically adopted techniques for the detection of COVID-19 including oligonucleotide-based molecular detection, Point-of-Care immunodiagnostics, radiographical analysis/sensing system, and newly developed biosensing prototypes having commercial viability. The commercial kits/analytical methods based-sensing strategies have also been tabulated categorically. The critical insights on the developer, commercial brand name, detection methods, technical operational details, detection time, clinical specimen, status, the limit of detection/detection ability have been discussed comprehensively. We believe that this review may provide scientists, clinicians and healthcare manufacturers valuable information regarding the most recent developments/approaches towards COVID-19 diagnosis.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas Biosensibles/métodos , Infecciones por Coronavirus/diagnóstico , Dispositivos Laboratorio en un Chip , Neumonía Viral/diagnóstico , Pruebas en el Punto de Atención , Animales , Anticuerpos Inmovilizados/química , Betacoronavirus/genética , Biomarcadores/análisis , Técnicas Biosensibles/instrumentación , COVID-19 , Repeticiones Palindrómicas Cortas Agrupadas y Regularmente Espaciadas , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/virología , Diseño de Equipo , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Nanoestructuras/química , Pandemias , Neumonía Viral/sangre , Neumonía Viral/virología , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA